Analysis of High Vibration Causing 211-P-25A Centrifugal Pump Damage in Hydrocraker Process

Authors

  • Eflita Yohana Department of Mechanical Engineering, Diponegoro University, Jl. Prof. Sudharto, SH., Semarang 50275, Indonesia
  • Bachtiar Yusuf Department of Mechanical Engineering, Diponegoro University, Jl. Prof. Sudharto, SH., Semarang 50275, Indonesia
  • Muhammad Arrafi Lazuardi Department of Mechanical Engineering, Diponegoro University, Jl. Prof. Sudharto, SH., Semarang 50275, Indonesia
  • Mohamad Endy Julianto Department of Chemical Engineering, Vocational School, Diponegoro University, Jl. Prof. Sudharto, SH., Semarang 50275, Indonesia
  • Vita Paramita Department of Chemical Engineering, Vocational School, Diponegoro University, Jl. Prof. Sudharto, SH., Semarang 50275, Indonesia

DOI:

https://doi.org/10.37934/arfmts.80.2.1321

Keywords:

High Vibration, Internal Recirculation, Cavitation, Centrifugal Pump

Abstract

The more developing technology enhances the need for energy; this requires the maximization of the performance of power plant components and energy. Refinery Unit (RU) is currently one of the real applications. Reliable equipment is required in running a massive industry. In running the oil production process at Refinery Unit (RU), the thing that needs to be put into consideration is pumps. A pump is a device for distributing fluids from one place to another. In Refinery Unit (RU), the pump is not only for oil but also for other fluids. In this research at Refinery Unit, the pump that is to be discussed is a centrifugal pump 211-P-25A. The objective of this research is to analyze the damage of pump 211-P-25A, which indicated high vibration. This causes the pump not to work optimally, so it requires the right maintenance. The research is done by using an analytical method, visual observation towards impeller and shaft, and comparing the results in accordance to API 610. Afterwards, the right maintenance will be known for centrifugal pump 211-P-25A to reduce the high vibration that occurred in the pump. High vibration may be caused by cavitation and internal recirculation. The damage in pump 211-P-25A is caused by repeated internal circulation, which causes damage to the impeller and high-speed shaft. Pump 211-P-25A experiences high vibration due to low flow. The flow produced is 2.67 m3/h, with a pump design minimum flow of 8.6 m3/h. This causes damage to pump components. Due to this damage, the performance of the pump will not be optimal, and its efficiency will be reduced.

References

Karassik, Igor J., and Terry McGuire. "Pump Operation at Off-Design Conditions." Centrifugal Pumps (1998): 558-591. https://doi.org/10.1007/978-1-4615-6604-5_22

Davis, Harmer Elmer, George Earl Troxell, and Clement Tehle Wiskocil. The Testing and Inspection of Engineering Materials (2nd edition). McGraw Hill, New York (1955).

World Pumps. "Pump cavitation and how to avoid it." Cavitation, 2018. www.worldspumps.com. https://doi.org/10.1016/S0262-1762(18)30146-9

Rahman, Abdul Razak Abdul, Eddy Azrai Ariffin, Muhammad Helmi Abu, Fudhail Abdul Munir, and Azma Putra. "Experimental Investigation of Thermally Induced Vibration in Sulphur Recovery Unit (SRU)." Journal of Advanced Research in Fluid Mechanics and Thermal Sciences 56, no. 1 (2019): 78-87.

Scheffer, Cornelius, and Paresh Girdhar. Practical machinery vibration analysis and predictive maintenance. Elsevier Science & Technology, 2004.

Latuny, Jonny. "A sensitivity comparison of Neuro-fuzzy feature extraction methods from bearing failure signals." PhD diss., Curtin University, 2013.

Adistya, Irman Supriadi. "Pengembangan sistem monitoring vibrasi pada kipas pendingin menggunakan accelerometer ADXL345 dengan metode FFT berbasis labview." PhD diss., Universitas Islam Syarif Hidayatullah, Jakarta, Indonesia (2014).

Agung, Samudra Budi, Poernomo Heroe, and Wirawan Husodo Adi. "Analisa Getaran Pada Air Fin Cooler Equipment 203-E-003-M4 Akibat Misalignment Poros." In Proceedings Conference on Marine Engineering and its Application, vol. 1, no. 1, pp. 13-18. 2018.

Husda, Syamsul Muarif. "Studi Literatur Tentang Program Pump System Improvement Modeling Tool Untuk Penyempurnaan Kinerja Sistem Pompa." PhD diss., Universitas Muhammadiyah Yogyakarta, Indonesia (2014).

Arrafi, Lazuardi. "Research data in Data Workshop Pump 211-P-25A." Refinery Unit, 2018.

Sundyne Corporation, "Operation & Control Installation." in Operation and Maintenance Manual LMV-322, ed. Sundyne Corp., USA: Sundyne (2009): 18-25.

Shneider, Jeumont. "Centrifugal Pump Performance Curve." in Pump Sepecialist Level 1, Texas, USA: Flow serve Learning Centre (2009): 94-130.

Fairfield, C. A. "Spatial, temporal, and thermal analysis of a cavitating high-pressure water-jet." Journal of Advanced Research in Fluid Mechanics and Thermal Sciences 18, no. 1 (2016): 1-19.

World Pumps. "Pump and Cavitation." Cavitation, 2018. www.worldspumps.com.

Fraser, Warren H. "Flow recirculation in centrifugal pumps." In Proceedings of the 10th Turbomachinery Symposium. Texas A&M University. Turbomachinery Laboratories, 1981.

Nikkiso-sundstrand. "Sundyne gearbox clearance inspection report." Higashimurayama Plant Report, USA, Nikkiso-Sundstrand Co. Ltd., 2018.

Standard, A. P. I. 610. "Centrifugal pumps for petroleum, petrochemical and natural gas industries." American Petroleum Institute 11th Edition (2010).

Arrafi, Lazuardi, "Research data (2nd ed.) in Data Workshop Pump 211-P-25A." Refinery Unit, 2018.

Volk, Michael. "Pump Characteristics and Applications." Boca Raton: CRC Press; 2nd Edition (2005).

Downloads

Published

2021-02-12

How to Cite

Eflita Yohana, Yusuf, B. ., Lazuardi, M. A., Julianto, M. E., & Vita Paramita. (2021). Analysis of High Vibration Causing 211-P-25A Centrifugal Pump Damage in Hydrocraker Process. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 80(2), 13–21. https://doi.org/10.37934/arfmts.80.2.1321